Aluminium Wiring

Aluminium Wiring Information

QUESTION
"Should I be concerned about a home containing Aluminium Wiring?"
ANSWER

Most electrical wire is made of copper. Copper is predominately used in residential construction with the exception of the service cable and single purpose high-amperage circuits such as sub-panels, electrical ranges or air conditioners. Since copper is a better conductor than aluminum, the aluminum wire must be larger to safely carry the same current as copper.

Some houses built or remodeled between the early 1950s and late 1970s were wired with aluminum . This wiring can be identified by the letters AL or the word ALUMINUM stamped on the plastic covering or cable. Don't confuse the brand name ALCAN with solely aluminum wiring. Alcan makes both copper and aluminum wiring for residential purposes.

There are basically three reasons why aluminum wiring may be of concern:

  1. it has a tendency to oxidize which increases the wire's resistance resulting in the wire overheating at the receptacle
  2. it is more malleable (softer) than copper and therefore easily nicked
  3. because of its high thermal expansion, it has a tendency to change shape at the terminal screws and thus become loose or creep off

Given its incompatibility with fittings designed for other. metals in the electrical system, improper connections may cause electrical resistance which in turn may cause overheating and fire. To overcome the incompatibility, the aluminum wiring may have been "pigtailed" with copper using proper connectors, (Marrette-brown; Ideal-purple)

WARNING SIGNS OF UNSAFE ALUMINUM WIRING:

  • unusually warm or warped outlets and switch cover plates
     
  • smoke or sparks coming from receptacles and switches
     
  • strange odors in the area of receptacles and switches
     
  • untraceable problems with plug-in lights and appliances
     
  • periodic flickering of lights

CARE TO BE TAKEN WITH ALUMINUM WIRING:

  • Do not overfuse aluminum wiring. The AWG (American Wire Gauge) rating of #12 aluminum wiring is equivalent to #14 copper wiring. Both are rated for 15 amps, so use only the t5 amp rated glass fuse, cartridge fuse or breaker for aluminum wiring stamped either 12/2 or 12/3.
     
  • Copper and Aluminum should never be connected together except using special anti-oxidant paste and crimped with approved clamp connectors. If you use twist-on connectors (wire-nuts or marrets) make sure they are approved for use with aluminum wiring.
     
  • When purchasing replacement receptacles, switches or fixtures ensure that they are compatible for aluminum wiring. Typically, receptacles that are approved for aluminum wiring will be stamped CO\.ALR, CU-AL or AL-CU indicating they can be used for both copper and aluminum.
     
  • Do not use receptacles stamped with AL and a line through it. These receptacles are incompatible with aluminum wiring.
    As part of your preventive maintenance plan for the home, check switches and receptacles by removing the cover plates and visually inspecting the wires
    for any signs of scorching, looseness, heat and/or odor.
     
  • Aluminum wiring is not handyman-friendly. If you suspect anything unusual, have a licensed electrician work on circuits with aluminum wiring.


For further information contact your local public utilities office or a licensed electrician.
 


Please Note:The information found in this section is provided as a service to our web site visitors.  While we attempt to ensure that all information is accurate and a fair depiction of real circumstances, it is to be used solely for information purposes. Home Inspectors® may not be held responsible for the accuracy of any of the above information. Re- production of any of this information is strictly prohibited without written permission of Home Inspectors®.

 